美國FDA質(zhì)量管理體系QSR820咨詢返回首頁

QSR 820 法規(guī)從1996年發(fā)布以來,歷史上進行了6次小型的技術修改。如下

 

Technical Amendment
Federal Register Citation

65 FR 17136
(31-Mar-2000)

Change removed paragraphs (e) and (f) from 820.1 Scope.

PART 820—QUALITY SYSTEM REGULATION
7. The authority citation for 21 CFR part 820 continues to read as follows:
Authority: 351, 352, 360, 360c, 360e, 360h, 360i, 360j, 360l, 371, 374, 381, 383.
8. Amend § 820.1 by removing paragraphs (e) and (f).


65 FR 66636
(07-Nov-2000)

Change restored paragraph (e) to 820.1 Scope.

 

PART 820—QUALITY SYSTEM REGULATION
5. The authority citation for 21 CFR part 820 continues to read as follows:
Authority: 21 U.S.C. 351, 352, 360, 360c, 360d, 360e, 360h, 360i, 360j, 360l, 371, 374, 381, 383.
6. Section 820.1 is amended by adding paragraph (e) to read as follows:
§ 820.1 Scope.
* * * * *
(e) Exemptions or variances. (1) Any person who wishes to petition for an exemption or variance from any device quality system requirement is subject to the requirements of section 520(f)(2) of the act. Petitions for an exemption or variance shall be submitted according to the procedures set forth in § 10.30 of this chapter, the FDA’s administrative procedures. Guidance is available from the Center for Devices and Radiological Health, Division of Small Manufacturers Assistance (HFZ–220), 1350 Piccard Dr., Rockville, MD 20850, U.S.A., telephone 1–800–638–2041 or 1–301–443–6597, FAX 301–443–8818.

(2) FDA may initiate and grant a variance from any device quality system requirement when the agency determines that such variance is in the best interest of the public health. Such variance will remain in effect only so long as there remains a public health need for the device and the device would not likely be made sufficiently available without the variance.


69 FR 11313
(10-Mar-2004)

Change removed reference to 21 CFR 804, which was deleted from the CFR.

 

PART 820—QUALITY SYSTEM REGULATION
14. The authority citation for 21 CFR part 820 continues to read as follows:
Authority: 21 U.S.C. 351, 352, 360, 360c, 360d, 360e, 360h, 360i, 360j, 360l 371, 374, 381, 383.
15. Section 820.198(d) is revised to read as follows
§ 820.198 Complaint files.
* * * * *
(d) Any complaint that represents an event which must be reported to FDA under part 803 of this chapter shall be promptly reviewed, evaluated, and investigated by a designated individual(s) and shall be maintained in a separate portion of the complaint files or otherwise clearly identified. In addition to the information required by § 820.198(e), records of investigation under this paragraph shall include a determination of:
(1) Whether the device failed to meet specifications;
(2) Whether the device was being used for treatment or diagnosis; and
(3) The relationship, if any, of the device to the reported incident or adverse event.
* * * * *
16. Section 820.200(c) is revised to read as follows:
§ 820.200 Servicing.
* * * * *

c) Each manufacturer who receives a service report that represents an event which must be reported to FDA under part 803 of this chapter shall automatically consider the report a complaint and shall process it in accordance with the requirements of § 820.198.


69 FR 29829
(25-May-2004)

Changed to specifically note applicability of 21

CFR 820 to tissue products, under newly released 21 CFR 1271.

Also, the Quality System regulation contains a typographic error: it has a date of 2005, but 2004 is the correct date.

 

PART 820—QUALITY SYSTEM REGULATION
6. The authority citation for 21 CFR part 820 is revised to read as follows:
Authority: 21 U.S.C. 351, 352, 360, 360c, 360d, 360e, 360h, 360i, 360j, 360l, 371, 374, 381, 383; 42 U.S.C. 216, 262, 263a, 264.
7. Section 820.1 is amended by adding two sentences to the end of paragraph (a)(1), and by revising paragraph (b) to read as follows:
§ 820.1 Scope.
(a) Applicability. (1) * * *
Manufacturers of human cells, tissues, and cellular and tissue-based products (HCT/Ps), as defined in § 1271.3(d) of this chapter, that are medical devices (subject to premarket review or notification, or exempt from notification, under an application submitted under the device provisions of the act or under a biological product license application under section 351 of the Public Health Service Act) are subject to this part and are also subject to the donor-eligibility procedures set forth in part 1271 subpart C of this chapter and applicable current good tissue practice procedures in part 1271 subpart D of this chapter. In the event of a conflict between applicable regulations in part 1271 and in other parts of this chapter, the regulation specifically applicable to the device in question shall supersede the more general.
* * * * *
(b) The quality system regulation in this part supplements regulations in other parts of this chapter except where explicitly stated otherwise. In the event of a conflict between applicable regulations in this part and in other parts of this chapter, the regulations specifically applicable to the device in question shall supersede any other generally applicable requirements.


71 FR 16228
(31-Mar-2006)

Change removed reference to 21 CFR 804, which was deleted from the CFR.

PART 820—QUALITY SYSTEM REGULATION
3. The authority citation for 21 CFR part 820 continues to read as follows:
Authority: 21 U.S.C. 351, 352, 360, 360c, 360d, 360e, 360h, 360i, 360j, 360l, 371, 374, 381, 383.

4. Amend paragraph (a)(3) of § 820.198 by removing ‘‘or 804’’.


72 FR 17397
(09-Apr-2007)

Change updated title, address, and phone numbers for DSMICA.

PART 820—QUALITY SYSTEM REGULATION

6. FDA is revising Sec.  820.1(e) and replacing “Division of Small Manufacturers Assistance (HFZ-220), 1350 Piccard Dr., Rockville, MD 20850, U.S.A., telephone 1-800-638-2041 or 1-301-443-6597, FAX 301-443-8818” with “Division of Small Manufacturers, International and Consumer Assistance (HFZ-220), 1350 Piccard Dr., Rockville, MD 20850, U.S.A., telephone 1-800-638-2041 or 240-276-3150, FAX 240-276-3151.”

企業(yè)介紹 | 法律聲明 | 網(wǎng)站地圖 | 認證查詢 | 資料下載 | 在線留言 | 聯(lián)系方式
上海沃華產(chǎn)品技術服務有限公司 Copyright 2025 m.lylbx.cn, 版權所有 滬ICP備16037738號-1
電話:021-51088618;400-016-1080 地址:上海市長寧區(qū)天山路641號慧谷白貓科技園1號樓701室
友情鏈接: CE認證 | BIM咨詢 | 深圳注冊公司

滬公網(wǎng)安備 31010502002363號


又大又粗欧美黑人AAAAA片 | 性生生活色欲片性按摩 | 久久国产免费观看精品1 | 中国特级黄一级**毛片 | 国模冰莲2013肥美人体自慰w | 亚洲精品乱码久久蜜桃аv天堂中文最新不卡 | 久久99精品久久久久久园产越南 | 肥老熟妇伦子伦456视频 | 日本DVD专区中文在线 | 未满十八18禁止免费无码网站 | 国内精品久久久久久久试看 | 国产综合色香蕉精品五夜婷 | 九九免费精品视频 | 永久免费精品影视网站 | 性饥渴艳妇K8经典色欲 | 农村女人一级毛片20岁的毛片 | 爱啪网亚洲第一福利网站 | 国产女主播喷水视频在线观看 | 亚洲a片无码一区二区蜜桃久久 | 91精品国产福利资源在线观看麻豆 | 把插八插露脸对白内射 | 91免费精品国偷自产在线不卡 | 91热久久免费频精品动漫99 | 快插我BB好爽舔我视频 | 另类内射国产在线 | 一本视频精品中文字幕 | 一本久道久久综合婷婷五月 | 一级a性色生活片久久无码火 | 国产精品亚洲精品专区 | 99国产精品久久久久99打野战 | 亚洲国产在线精品一区在 | 好紧好爽好疼的免费视频全集完整版在线播放 | 日本国产一区在线观看 | 黄色视频网站在线观看 | 精品性影院一区二区三区内射 | 亚洲一日欧美日韩中文字幕 | 纯肉高H肉辣浪荡NP论J | 特黄四级人牲片在线观看 | 亚洲日韩在线男人视频网站 | 欧美日本韩国一二区视频 | 日本VS亚洲VS韩国一区三区四区 |